Sample Preparation & Automation

ET70 Automated Sample Pre-Processing System

Automated aliquoting, dilution and mixing for blood and urine samples, feeding straight into ICP-MS, LC-MS/MS and GC-MS workflows. Up to 96 tubes per run, with the manual pipetting step removed.

The ET70 Automated Sample Pre-Processing System, an enclosed benchtop autosampler for blood and urine tubes

The step before the instrument

Sample preparation is where throughput is lost and where variability creeps into a result that the mass spectrometer will faithfully reproduce. Manual aliquoting and dilution is slow, it is hard to audit, and its reproducibility depends on who is at the bench that day.

The ET70 automates that front end. Tubes are scanned, uncapped, mixed, aspirated, diluted and dispensed inside an enclosed environment, with liquid-level detection and reagent monitoring running throughout. What reaches your LC-MS/MS, ICP-MS or GC-MS is prepared the same way every run.

Key features

Automated front-end preparation for blood and urine, up to 96 tubes per run.

High throughput

Up to 96 sample tubes per run, unattended.

Blood and urine

Venous blood, peripheral blood and urine sediment tubes.

Precise pipetting

20 to 175 µL. Down to ±1.5% accuracy and 1.0% CV at 150 µL.

Full tube handling

Automatic barcode scan, mixing, and cap open and close.

Hands-off dilution

Automatic aspiration, dispensing and dilution.

Monitored and enclosed

Liquid and reagent level detection, self-check and fault alarms.

Laboratory staff working with racked blood collection tubes in a clinical pathology laboratory

Key applications

  • Clinical and pathology laboratories: Blood and urine preparation ahead of LC-MS/MS or ICP-MS analysis.
  • Toxicology: Consistent aliquoting and dilution across large sample batches.
  • Drugs of abuse screening: Repeatable preparation where throughput and auditability both matter.
  • Research laboratories: Removing operator-to-operator variability from study sample sets.

Specifications

Sample types
Blood and urine
Tube capacity
Up to 96 sample tubes per run
Sample volume
20 to 175 µL
Automated steps
Barcode scanning, tube mixing, tube opening and closing, sample aspiration and dispensing, dilution
Monitoring
Sample liquid-level detection and reagent-level monitoring
Pipette tips
Disposable, conductive or non-conductive
Processing environment
Enclosed
Diagnostics
Automatic system self-check with fault alarms

Supported tube sizes

  • 13 × 75 mm venous blood tubes
  • 13 × 100 mm venous blood tubes
  • 17 × 100 mm urine sediment tubes
  • Peripheral blood tubes approximately 8 to 10 mm diameter, 40 to 45 mm length

Gripper force and gripping range are adjustable, so minor variation in tube dimensions can generally be accommodated.

Pipetting performance

Volume Accuracy Precision
50 µL ±2.0% ≤3.0% CV
100 µL ±2.0% ≤2.0% CV
150 µL ±1.5% ≤1.0% CV

Australia and New Zealand

Market introduction pricing available

We have introduction pricing for the ET70 in Australia and New Zealand. It includes:

  • Standalone software adaptation
  • Installation
  • Initial operator training
  • Workflow setup support
Get in touch now

Pricing on application. We will send a written quotation for your configuration.

Talk to a local specialist

Tell us your sample type, tube format and throughput, and we will tell you honestly whether the ET70 fits your workflow.

Get in touch now

For research and industrial use only.